NFPA 70 | National Electrical Code | Noteworthy 2026 Tentative Interim Amendments
Issued Tentative Interim Amendments
TIA 26-1 | 680.21(C) — Swimming Pool Motors: Ground-Fault Protection
TIA 26-2 | 690.12(C) — Photovoltaic Systems: Rapid Shutdown Initiation Devices
TIA 26-3 | 430.132 (New) — Motors, Motor Circuits and Controllers
TIA 26-4 | 500.30(A) — Hazardous (Classified) Locations: Bonding
TIA 26-5 | 501.15(B)(2) — Class I, Division 2 Boundary Sealing
TIA 26-6 | 505.30(A) — Zone 0, 1 and 2 Hazardous Locations: Bonding
TIA 26-7 | 506.30(A) — Zone 20, 21 and 22 Hazardous Locations: Bonding
TIA 26-8 | 270.50 — Grounding Electrode Systems Over 1000 Volts AC / 1500 Volts DC
Proposed Tentative Interim Amendments
Proposed TIA 1874 | 625.43(D) — Electric Vehicle Power Transfer Systems: Emergency Shutoff
Proposed TIA 1892 | 625.54 — Electric Vehicle Power Transfer Systems: GFCI Protection for Personnel
Proposed TIA 1896 | 225.31(B) — Outside Branch Circuits and Feeders: Location of Disconnecting Means
Proposed TIA 1897 | Table 501.10(A)(1) — Class I, Division 1 Wiring Methods
Proposed TIA 1903 | 700.6(C) — Emergency Systems: Bypass and Isolation of Transfer Equipment
Proposed TIA 1912 | 624.44(A) — Electric Self-Propelled Vehicle Power Transfer Systems: Equipment Connection
Proposed TIA 1915 | Tables 270.122(B)(1), (B)(2) and (B)(3) — Equipment Grounding Conductors
Tentative Interim Amendments become effective between regular editions of NFPA 70. Proposed TIAs remain subject to the NFPA standards-development process and should be distinguished from issued TIAs incorporated into the current Code.
Check with Jeff Sargent for more information: jsargeant@nfpa.org
NFPA 70 | Tentative Interim Amendments. Among the more consequential Tentative Interim Amendments for educational and healthcare settlements are proposals affecting emergency transfer equipment, electric vehicle charging and building disconnects.
700.6(C) — Emergency Transfer Equipment: Proposed revisions address bypass and isolation requirements for transfer equipment, with implications for maintaining emergency electrical systems without unnecessarily interrupting the loads those systems are intended to protect.
625.54 — Electric Vehicle Supply Equipment: Proposed revisions address GFCI protection and its interaction with EV charging equipment, an increasingly important issue for campus fleet, commuter and residential charging infrastructure.
225.31(B) — Building Disconnects: Proposed revisions address the location of disconnecting means for separately supplied buildings and structures, a practical concern for large educational settlements with distributed feeders, substations and multiple buildings under common management.
“`