The purpose of the code is to establish minimum requirements to provide a reasonable level of health, safety, property protection and welfare by controlling the design, location, use or occupancy of all buildings and structures through the regulated and orderly development of land and land uses within this jurisdiction.
CLICK IMAGE
Municipalities usually have specific land use or zoning considerations to accommodate the unique needs and characteristics of college towns:
Mixed-Use Zoning: Cities with colleges and universities often employ mixed-use zoning strategies to encourage a vibrant and diverse urban environment. This zoning approach allows for a combination of residential, commercial, and institutional uses within the same area, fostering a sense of community and facilitating interactions between students, faculty, and residents.
Height and Density Restrictions: Due to the presence of educational institutions, cities may have specific regulations on building height and density to ensure compatibility with the surrounding neighborhoods and maintain the character of the area. These restrictions help balance the need for development with the preservation of the existing urban fabric.
Student Housing: Cities with colleges and universities may have regulations or guidelines for student housing to ensure an adequate supply of affordable and safe accommodations for students. This can include requirements for minimum bedroom sizes, occupancy limits, and proximity to campus.
Parking and Transportation: Given the concentration of students, faculty, and staff, parking and transportation considerations are crucial. Cities may require educational institutions to provide parking facilities or implement transportation demand management strategies, such as promoting public transit use, cycling infrastructure, and pedestrian-friendly designs.
Community Engagement: Some cities encourage colleges and universities to engage with the local community through formalized agreements or community benefit plans. These may include commitments to support local businesses, contribute to neighborhood improvement projects, or provide educational and cultural resources to residents.
This is a relatively new title in the International Code Council catalog; revised every three years in the Group B tranche of titles. Search on character strings such as “zoning” in the link below reveals the ideas that ran through the current revision:
Reed v. Town of Gilbert (2015): This Supreme Court case involved a challenge to the town of Gilbert, Arizona’s sign code, which regulated the size, location, and duration of signs based on their content. The court held that the sign code was a content-based restriction on speech and therefore subject to strict scrutiny.
City of Ladue v. Gilleo (1994): In this Supreme Court case, the court struck down a municipal ordinance that banned the display of signs on residential property, except for signs that fell within specific exemptions. The court held that the ban was an unconstitutional restriction on the freedom of speech.
Metromedia, Inc. v. San Diego (1981): This Supreme Court case involved a challenge to a San Diego ordinance that banned off-premises advertising signs while allowing on-premises signs. The court held that the ordinance was an unconstitutional restriction on free speech, as it discriminated against certain types of speech.
City of Ladue v. Center for the Study of Responsive Law, Inc. (1980): In this Supreme Court case, the court upheld a municipal ordinance that prohibited the display of signs on public property, but only if the signs were posted for longer than 10 days. The court held that the ordinance was a valid time, place, and manner restriction on speech.
City of Boerne v. Flores (1997): This Supreme Court case involved a challenge to a municipal sign code that regulated the size, location, and content of signs in the city. The court held that the sign code violated the Religious Freedom Restoration Act, as it burdened the exercise of religion without a compelling government interest.
Mike Anthony is ID Number 469 | Proposal period closes 11:59 PM US Pacific Time | May 15
Meeting Notes in red
Loss of electric power and internet service happens more frequently and poses at least an equal — if not greater threat — to public safety. So why does neither the National Electrical Code or the National Electrical Safety Code integrate reliability into their core requirements? Reliability requirements appear in a network of related documents, either referenced, or incorporated by reference; sometimes automatically, sometimes not.
NESC Main Committee Membership: Page xii
Apart from the IEEE as the accredited standards developer, there are no “pure non-government user-interests” on this committee; although ANSI’s Essential Requirements for balance of interests provides highly nuanced interpretation. The Classifications on Page xiii represents due diligence on meeting balance of interest requirements.
In our case, we are one of many large universities that usually own district energy plants that both generate and purchase generate electric power (as sometimes provide var support to utilities when necessary; as during the August 2003 North American outage). For University of Michigan, for example, has about 20 service points at 4.8 – 120 kV. Its Central Power Plant is the largest cogeneration plant on the DTE system.
Contents: Page xxviii | PDF Page 29
Absence of internet service is at least as much a hazard, and more frequent, than downed wires. Is there a standards solution? Consideration of interoperability of internet service power supported on utility poles should track in the next revision.
No mention of any reliability related IEEE reliability standards in the present edition. Why is this?
Section 2: Definitions of Special Terms| PDF Page 46
In the 2023 Handbook, the term “reliability” shows up 34 times.
availability (from Bob Arno’s IEEE 3006-series and IEEE 493 Gold Book revision)
reliability (Bob Arno)
utility (PDF Page 57)
communication | PDF Page 47
list of terms defined in the 2023 National Electrical Code that are new and relevant to this revision: (Article 100 NEC)
municipal broadband network, digital subscriber line, surveillance cameras
wireless communication system
010. Purpose | PDF Page 40
Looks like improvement since last edition. Suggest explicit Informational Note, as in the NEC, using “reliability” and referring to other agencies. “Abnormal events” could be tighter and refer to other standards for abnormal, steady-state events. The clarification of purpose is welcomed although a great deal remains uncovered by other best practice literature; though that can be repaired in this edition.
Legacy of shared circuit path standards. Should provisions be made for municipal surveillance, traffic and vehicle control infrastructure. What would that look like?
011. Scope | Covered PDF Page 40
3. Utility facilities and functions of utilities that either (a) generate energy by conversion from some other form of energy such as, but not limited to, fossil fuel, chemical, electrochemical, nuclear, solar, mechanical, wind or hydraulic or communication signals, or accept energy or communication signals from another entity, or (b) provide that energy or communication signals through a delivery point to another entity.
5. Utility facilities and functions on the line side of the service point supplied by underground or overhead conductors maintained and/or installed under exclusive control of utilities located on public or private property in accordance with legally established easements or rights-of-way, contracts, other agreements (written or by conditions of service), or as authorized by a regulating or controlling body. NOTE: Agreements to locate utility facilities on property may be required where easements are either (a) not obtainable (such as locating utility facilities on existing rights-of-way of railroads or other entities, military bases, federal lands, Native American reservations, lands controlled by a port authority, or other governmental agency), or (b) not necessary (such as locating facilities necessary for requested service to a site).
012. General Rules | Covered PDF Page 42
For all particulars not specified, but within the scope of these rules, as stated in Rule 011A, design, construction, operation, and maintenance should be done in accordance with accepted good practice for the given local conditions known at the time by those responsible for the communication or supply lines and equipment
General purpose clause could use some work since no definition of “accepted good practice”. Refer to IEEE bibliography.
Section 2: Definition of special terms | PDF Page 46
Recommendations elsewhere should track here.
The word “installation” appears 256 times and is generally understood in context by experts. Suggest borrow from NEC to clarify our concern for including co-linear/communication circuits.
conduit. exclusive control, lines, photovoltaic, NEC interactive. qualified
Section 3: Reference
NFPA 70®, National Electrical Code® (NEC®). [Rules 011B4 NOTE, 099C NOTE 1, and 127
IEEE Std 4™-1995, IEEE Standard Techniques for High-Voltage Testing. [Table 410-2 and Table 410-3]
IEEE Std 516™-2009, IEEE Guide for Maintenance Methods on Energized Power-Lines. [Rules 441A4
NOTE 2, 446B1, and 446D3 NOTE, and Table 441-5, Footnote 4]
IEEE Std 1427™-2006, IEEE Guide for Recommended Electrical Clearances and Insulation Levels in
Air-Insulated Electrical Power Substations. [Rule 124A1 NOTE, Table 124-1, 176 NOTE, and 177 NOTE]
IEEE Std 1584™-2002, IEEE Guide for Performing Arc Flash Hazard Calculations. [Table 410-1,
Footnotes 1, 3, 6, and 14]
IEEE Std C62.82.1™-2010, IEEE Standard for Insulation Coordination—Definitions, Principles, and Rules.
[Table 124-1 Footnote 5]
Add references to Gold Book, 1386, etc. IEC since multinationals conform.
Safety Rules for the Installation and Maintenance of Overhead Electric Supply and Communication Line | PDF Page 111
Has anyone confirmed that these tables match NEC Table 495.24 lately? If it helps: there were no meaningful changes in the 2023 NEC in Article 495, the high voltage article
Section 11. Protective arrangements in electric supply stations | PDF Page 77
A safety sign shall be displayed on or beside the door or gate at each entrance. For fenced or walled electric supply stations without roofs, a safety sign shall be displayed on each exterior side of the fenced or wall enclosure. Where the station is entirely enclosed by walls and roof, a safety sign is required only at ground level entrances. Where entrance is gained through sequential doors, the safety sign should be located at the inner door position. (A clarification but no change. See Standards Michigan 2017 proposals)
Recommend that all oil-filled cans be removed and services upgraded through energy regulations with new kVA ratings
Section 12: Installation and maintenance of equipment
093. Grounding conductor and means of connection
Fences The grounding conductor for fences required to be effectively grounded by other parts of this Code shall meet the requirements of Rule 093C5 or shall be steel wire not smaller than Stl WG No. 5.
D. Guarding and protection | PDF Page 67
124. Guarding live parts| PDF Page 85
Propose roofs required for exterior installations
Part 2. Safety Rules for the Installation and Maintenance of Overhead Electric Supply and Communication Line | Page 72
Section 22. Relations between various classes of lines and equipment | Page 80
222. Joint use of structures | Page 82
Where the practice of joint use is mutually agreed upon by the affected utilities, facilities shall be subject to the appropriate grade of construction specified in Section 24. Joint use of structures should be
considered for circuits along highways, roads, streets, and alleys. The choice between joint use of structures and separate lines shall be determined through cooperative consideration with other joint
users of all the factors involved, including the character of circuits, worker safety, the total number and weight of conductors, tree conditions, number and location of branches and service drops, structure
conflicts, availability of right-of-way, etc.
Reliability considerations for sustaining internet service when power supply is absent.
Par2 Section 20 Safety Rules for the Installation and Maintenance of Overhead Electric Supply and Communication Line | PDF Page 111
Has anyone confirmed that these tables match NEC Table 495.24 lately?
Part 3. Safety Rules for the Installation and Maintenance of Underground Electric Supply and Communication Lines | Page 220
Renewable energy for internet access
311. Installation and maintenance
A. Persons responsible for underground facilities shall be able to indicate the location of their facilities.
B. Reasonable advance notice should be given to owners or operators of other proximate facilities that
may be adversely affected by new construction or changes in existing facilities.
C. For emergency installations, supply and communication cables may be laid directly on grade if the
cables do not unreasonably obstruct pedestrian or vehicular traffic and either:
1. The cables are covered, enclosed, or otherwise protected, or
2. The locations of the cables are conspicuous.
Supply cables operating above 600 V shall meet either Rule 230C or 350B.
NOTE: See Rules 014B2 and 230A2d.
Part 4. Work Rules for the Operation of Electric Supply and Communications Lines and Equipment | PDF Page 289
When and why was the term “Work” added to the title of this section?
Core text for the definition of wireless communication system reliability
Appendix E Bibliography| PDF Page 355
Index | PDF Page 398
The word “reliability” appears only three times. Should it track in the NESC or should it track in individual state requirements. So neither the NEC nor the NESC couples closely with power and communication reliability; despite the enormity and speed of research.
Branch circuits relevant to modular classroom buildings are primarily addressed in Article 120: Branch Circuits (formerly Article 210 in previous editions). This article covers requirements for branch-circuit sizing, overcurrent protection, outlets, and general installation rules for circuits up to 1000 volts AC or 1500 volts DC. Key sections include:120.19: Conductor sizing and derating.
120.20: Overcurrent protection.
120.21: Receptacle outlets and tamper-resistant requirements.
120.23: Specific rules for appliances and fixed equipment.
For outside branch circuits, see Article 267: Outside Branch Circuits and Feeders over 1000 Volts AC or 1500 Volts DC, Nominal (if applicable to higher voltages).Feeder Circuit RulesFeeder circuits are primarily addressed in Article 121: Feeders (formerly Article 215 in previous editions). This article details feeder conductor sizing, grounding, and disconnecting means for circuits supplying branch circuits or sub-feeders up to 1000 volts AC or 1500 volts DC.Key sections include:121.2: Minimum rating and sizing.
121.3: Overcurrent protection.
121.4: Feeders as branch circuits (when applicable).
Outside feeders are covered in Article 267: Outside Branch Circuits and Feeders over 1000 Volts AC or 1500 Volts DC, Nominal (for higher voltages) or cross-referenced in Article 267 for general outside installations.
For modular school buildings detached from the main building with pre-installed single or three phase wiring systems, designers must choose between a separate service drop from a merchant utility or tapping into an existing source from the nearby school building.
Compact Muon Solenoid / European Organization for Nuclear Research
Modular classroom buildings, often prefabricated and portable, require special attention in electrical power design to ensure safety, compliance, and functionality. The 2026 National Electrical Code (NEC) emphasizes proper sizing of branch circuits (Article 120) and feeders (Article 121) based on load calculations (Article 122), accounting for lighting, HVAC, and technology demands. Designers must consider temporary or relocatable installations, ensuring grounding and bonding comply with Article 250 for safety. Flexible wiring methods, like cord-and-plug connections, may be needed for portability, per Article 400. Modular units often face environmental challenges, requiring weather-resistant materials and equipment (Article 110). Surge protection (Article 285) is critical to safeguard sensitive classroom electronics. Accessibility for maintenance and inspections, per Article 110.26, is vital due to compact designs. Finally, compliance with local codes and coordination with utility connections ensure reliable power delivery for educational environments.
We have tried for several cycles to change the “Type of Occupancy” listing in NEC Table 220.12 to reflect more granular definition for School/university and Sports arena lighting load calculations. We will have another chance in the 2026 NEC. [Public input is due September 10th]
Public Input Closing Date: September 7, 2023
4 February 2021
Let’s start marking up the 2023 National Electrical Code, shall we? We will collaborate with IEEE Standards Coordinating Committee 18 — the committee that follows NFPA electrical safety consensus products and coordinates the response of IEEE electrical power professionals.
A good place to start is with the transcripts of the 2020 revision — AVAILABLE HERE for free. We look for proposals that failed for one reason or another; holding fast to our hunch that changes to the ampere load requirements that appear in the prescriptive statements to designers and inspectors of Chapter 2 could changed. The 2020 transcripts of Code-Making Panel 4 are linked below:
We have been trying for several NEC revision cycles to change the “Type of Occupancy” tabulations of Table 220.12 to reflect more granular definition in the Volt/Ampere requirement of 33 VA/m2 (3 VA/ft2) for School/university and Sports arena. Some of the problem in Table 220.12 regarding electrical loads in education facilities lies in its foundation built upon the International Building Code; the remainder of the problem lies with the education facility industry itself; described in detail in our ABOUT.
The good news is that the NFPA Fire Protection Research Foundation (FPRF) recognizes the problem and is acting on it; described in previous posts and in its project portfolio. Keep in mind that Standards Michigan, the original voice of the user-interest for education facility industry in the global standards system, has to compete with other, competitor stakeholders who make their market in this and in other consensus products accredited by the American National Standards Institute.
Public input for the 2023 National Electrical Code is due September 10th. We will collaborate with the FPRF and the IEEE Education & Healthcare Facilities Committee, and others, to get informed public input to Code-Making Panel 2 and the NEC Technical Correlating Committee. See our CALENDAR for our next Electrical & Telecommunication teleconference, open to everyone.
Issue: [19-201]
Category: Electrical
Colleagues: Mike Anthony, Scott Gibb, Jim Harvey, Kane Howard, Paul Kempf, Philip Ling, Jose Meijer
Disagree with someone and cannot persuade them? Do you need to hide your intransigence or ulterior motive? Then change the basis of discussion by changing the subject with a different definition.
This happens routinely in political discourse and rather frequently in best practice discovery and promulgation in building construction and settlement infrastructure standards[1]. Assuming all parties are negotiating in good faith resolution may lie in agreement on a common understanding of what a satisfying agreement might look like.
Admittedly, a subtle and challenging topic outside our wheelhouse[2] hence the need to improve our organization of this topic starting with today’s colloquium; with follow on sessions every month.
Starting 2025 we will organize our approach to this topic, thus:
Language 100. Survey of linguistic basics for developing codes, standards and regulations. Many vertical incumbents have developed their own style manuals
Language 200. Electrotechnical vocabulary
Language 300. Architectural and Allied trade vocabulary
Language 400. The language of government regulations; the euphemisms of politicians with influence over the built environment
Language 500. Advanced topics such as large language models or spoken dialects such as “High Michigan” — arguably, the standard American dialect where it applies to the standards listed above.
It may not be obvious how profound the choice of words and phrases have on leading practice discovery and promulgation. For example, “What is Gender” determines the number, placement and functionality of sanitary technologies in housing, hospitals and sporting. The United States has a Supreme Court justice that cannot define “woman”
As always, we will respond to public consultation opportunities wherever we can find them. Some organizations are better than this than others.
Today we limit our discussion to language changes in the catalogs of ANSI-accredited standards developers whose titles have the most influence over the interoperability of safety and sustainability technologies that create and sustain the built environment of educational settlements.
Every building construction discipline has its own parlance and terms of art.
This is enough for a one-hour session and, depending upon interest, we will schedule a breakout session outside of our normal “daily” office hours. Use the login credentials at the upper right of our home page.
ΒΙΒΛΙΟΘΗΚΕΣ
Starting 2024 and running into 2025 we will break down this topic further, starting with construction contract language — Lingua Franca 300:
Asset management applies to any organization. As such, understanding its terminology, principles, and outcomes is key to an organization’s success. ISO 55000:2024 provides an overview of #AssetManagement and its expected benefits. @isostandardshttps://t.co/XZsWvJJ8r4
(1) The United States government defines a “Green Building” as a building that has been designed, constructed, and operated in a way that reduces or eliminates negative impacts on the environment and occupants. The government has established various standards and certifications that buildings can achieve to be considered “green.”
The most widely recognized green building certification in the United States is the Leadership in Energy and Environmental Design (LEED) certification, which is administered by the U.S. Green Building Council (USGBC). To achieve LEED certification, a building must meet certain standards related to sustainable site development, water efficiency, energy efficiency, materials selection, and indoor environmental quality.
In addition to the LEED certification, there are other programs and standards that can be used to measure and certify the sustainability of buildings, such as the Green Globes rating system and the Living Building Challenge.
Overall, the goal of green building is to create buildings that are not only environmentally sustainable but also healthier, more comfortable, and more efficient for occupants, while reducing energy consumption and greenhouse gas emissions. By promoting green building practices, the U.S. government aims to reduce the environmental impact of the built environment and move towards a more sustainable future.
(2) The U.S. Green Building Council is a conformance organization. See the discussion our ABOUT for background on incumbent stakeholders.
The National Institute of Standards and Technology seeks information to assist in carrying out several of its responsibilities under the Executive order on Safe, Secure, and Trustworthy Development and Use of Artificial Intelligence issued on October 30, 2023. Among other things, the E.O. directs NIST to undertake an initiative for evaluating and auditing capabilities relating to Artificial Intelligence (AI) technologies and to develop a variety of guidelines, including for conducting AI red-teaming tests to enable deployment of safe, secure, and trustworthy systems.
Attention Is All You Need | Authors: Ashish Vaswani et al. (2017). This groundbreaking paper introduced the Transformer architecture, replacing recurrent layers with self-attention mechanisms to enable parallelizable, efficient sequence modeling. It laid the foundational blueprint for all subsequent LLMs, revolutionizing natural language processing by capturing long-range dependencies without sequential processing.
BERT: Pre-training of Deep Bidirectional Transformers for Language Understanding | Authors: Jacob Devlin et al. (2018). BERT pioneered bidirectional pre-training via masked language modeling, allowing models to understand context from both directions. As an encoder-only Transformer, it achieved state-of-the-art results on 11 NLP tasks and established the pre-training/fine-tuning paradigm that underpins bidirectional LLMs like those in search and classification.
Training Compute-Optimal Large Language Models | Authors: Jordan Hoffmann et al. (2022). Known as the Chinchilla paper, it revealed that optimal LLM performance requires balanced scaling of model size and data volume (e.g., 70B parameters trained on 1.4T tokens outperform larger models with less data). This shifted research toward data-efficient training, influencing efficient LLM development.
Did you know? If you’ve seen clocks advertised to consumers as “atomic clocks,” those are actually listening to NIST radio stations’ time signals so they can count the seconds accurately. pic.twitter.com/hTTO0smikl
— National Institute of Standards and Technology (@NIST) January 31, 2024
Title: IEEE P3119 – Standard for the Procurement of Artificial Intelligence and Automated Decision Systems
Scope: The IEEE P3119 standard establishes a uniform set of definitions and a process model for procuring Artificial Intelligence (AI) and Automated Decision Systems (ADS). It covers government procurement, in-house development, and hybrid public-private development of AI/ADS. The standard redefines traditional procurement stages—problem definition, planning, solicitation, critical evaluation (e.g., impact assessments), and contract execution—using an IEEE Ethically Aligned Design (EAD) foundation and a participatory approach to address socio-technical and responsible innovation considerations. It focuses on mitigating unique AI risks compared to traditional technologies and applies to commercial AI products and services procured through formal contracts.
Purpose: The purpose of IEEE P3119 is to help government entities, policymakers, and technologists make transparent, accountable, and responsible choices in procuring AI/ADS. It provides a framework to strengthen procurement processes, ensuring due diligence, transparency about risks, and alignment with public interest. The standard aims to minimize AI-related risks (e.g., bias, ethical concerns) while maximizing benefits, complementing existing procurement practices and shaping the market for responsible AI solutions. It supports agencies in critically evaluating AI tools, assessing vendor transparency, and integrating ethical considerations into procurement.
Developmental Timelines:
September 23, 2021: The IEEE Standards Association (SA) Standards Board approved the project and established the IEEE P3119 Working Group. The Project Authorization Request (PAR) was created to define the scope.
2021–Ongoing: Development continues, with no final publication date confirmed in available sources. As of July 18, 2024, the standard was still in progress, focusing on detailed process recommendations.
The standard is being developed as a voluntary socio-technical standard, with plans to test it against existing regulations (e.g., via regulatory sandboxes).
By Whom:
Working Group Chair: Gisele Waters, Ph.D., Director of Service Development and Operations at Design Run Group, co-founder of the AI Procurement Lab, and a human-centered design researcher focused on risk mitigation for vulnerable populations.
Working Group Vice Chair: Cari Miller, co-founder of the AI Procurement Lab and the Center for Inclusive Change, an AI governance leader and risk expert.
IEEE P3119 Working Group: Comprises a global network of IEEE SA volunteers from diverse industries, collaborating to develop standards addressing market needs and societal benefits. The group integrates expertise from government workers, policymakers, and technologists.
Inspiration: The standard was inspired by the AI and Procurement: A Primer report from the New York University Center for Responsible AI.
The IEEE P3119 standard is a collaborative effort to address the unique challenges of AI procurement, emphasizing ethical and responsible innovation for public benefit
Title: IEEE P3120 – Standard for Quantum Computing Architecture
Scope: The IEEE P3120 standard defines a general architecture for quantum computers, focusing on the structure and organization of quantum computing systems. It covers the overall system architecture, including quantum hardware components (e.g., qubits, quantum gates), control systems, interfaces with classical computing systems, and software layers for programming and operation. The standard aims to provide a framework for designing interoperable and scalable quantum computing systems, addressing both hardware and software considerations for quantum and hybrid quantum-classical architectures.
Purpose: The purpose of IEEE P3120 is to establish a standardized framework to guide the design, development, and integration of quantum computing systems. It seeks to ensure consistency, interoperability, and scalability across quantum computing platforms, facilitating innovation and collaboration in the quantum computing ecosystem. By providing clear architectural guidelines, the standard supports developers, researchers, and industry stakeholders in building reliable and efficient quantum computers, bridging the gap between theoretical quantum computing and practical implementation.
Developmental Timelines:
September 21, 2023: The IEEE Standards Association (SA) Standards Board approved the Project Authorization Request (PAR) for P3120, initiating the project under the IEEE Computer Society’s Microprocessor Standards Committee (C/MSC).
2023–Ongoing: Development is in progress, with no confirmed publication date in available sources. As a standards development project, it involves iterative drafting, review, and consensus-building, typical of IEEE processes, which can span several years.
The standard is being developed as a voluntary standard, with potential for testing and refinement through industry and academic collaboration.
By Whom:
Sponsor: IEEE Computer Society, specifically the Microprocessor Standards Committee (C/MSC), which oversees standards related to microprocessor and computing architectures.
Working Group: The IEEE P3120 Working Group consists of volunteers from academia, industry, and research institutions with expertise in quantum computing, computer architecture, and related fields. Specific chairs or members are not detailed in available sources, but IEEE SA working groups typically include global experts from relevant domains.
Stakeholders: The development involves contributions from quantum computing researchers, hardware manufacturers, software developers, and standardization experts to ensure a comprehensive and practical standard.
The IEEE P3120 standard is a critical step toward formalizing quantum computing architectures, aiming to support the growing quantum technology industry with a robust and interoperable framework.
Since so much of what we do in standards setting is built upon a foundation of a shared understanding and agreement of the meaning of words (no less so than in technical standard setting) that time is well spent reflecting upon the origin of the nouns and verbs of that we use every day. Best practice cannot be discovered, much less promulgated, without its understanding secured with common language.
“The Water Is Wide” is a traditional folk song with deep roots in the British Isles, particularly Scotland and England, before it became a beloved American folk song. Its origins are complex, as it evolved through oral tradition, with variations in lyrics, melody, and title across regions and centuries. Below is a detailed explanation of its origins and journey to becoming a classic American folk song with summer associations.1. British Isles Origins (17th–18th Century)
Earliest Roots: The song likely derives from a Scottish or English folk ballad dating back to at least the 17th century. It is closely related to ballads like “Waly, Waly” (sometimes spelled “Wally, Wally”), a lament about love and loss. The earliest known versions appear in Scottish oral traditions, with references to broadsides (printed song sheets) from the 1600s.
Melody and Structure: The melody associated with “The Water Is Wide” is a modal, haunting tune typical of Celtic folk music. It shares similarities with other traditional songs like “O Waly, Waly,” which was collected in Cecil Sharp’s English Folk Songs from the Southern Appalachians (1917). The song’s structure, with its simple, repetitive stanzas, made it adaptable for oral transmission.
Lyrics and Themes: Early versions focused on themes of unrequited or lost love, with the “wide water” symbolizing an insurmountable barrier between lovers. For example, a common early stanza is: “The water is wide, I cannot get o’er / And neither have I wings to fly / Give me a boat that will carry two / And both shall row, my love and I.” This imagery of rivers and separation resonated in pastoral settings, often evoking summer landscapes.
2. Transmission to America
Colonial Migration: The song crossed the Atlantic with British and Scottish immigrants, particularly during the 17th and 18th centuries, settling in regions like the Appalachian Mountains, where it became part of the American folk tradition. Scots-Irish settlers, in particular, brought ballads like “The Water Is Wide” to the American South, where they were adapted to local contexts.
Appalachian Influence: In the Appalachians, the song’s lyrics and melody were shaped by oral tradition, with variations emerging in different communities. It retained its melancholic tone but often incorporated local imagery, such as American rivers or landscapes, which tied it to summer’s reflective, open-air mood.
African American Influence: Some scholars suggest that African American spirituals influenced the song’s evolution in America, as its themes of longing and crossing water paralleled spirituals like “Deep River.” This blending enriched its emotional depth and melodic variations.
3. Documentation and Revival
Early Collections: The song was first formally documented in the 19th century, with variants appearing in folk song collections. By the early 20th century, collectors like Cecil Sharp and Francis James Child (known for the Child Ballads) noted versions of “Waly, Waly” and related songs in both Britain and America.
Folk Revival (20th Century): “The Water Is Wide” gained prominence during the American folk revival of the 1950s and 1960s. Artists like Pete Seeger, Joan Baez, and The Kingston Trio popularized it, often performing it at summer folk festivals. Seeger’s version, in particular, standardized the modern American melody and lyrics, emphasizing its gentle, summery river imagery.
Adaptations: The song was adapted into various forms, including gospel, pop, and classical arrangements. Its inclusion in school songbooks and campfires further cemented its place in American folk culture, with its river imagery evoking lazy summer days.
6. Historical Significance
Oral Tradition: The song’s survival through oral tradition highlights its adaptability and emotional resonance, key traits of folk music.
Cross-Cultural Exchange: Its journey from Scotland/England to America, with influences from African American traditions, exemplifies the blending of cultures in American folk music.
Modern Legacy: Today, “The Water Is Wide” remains a staple in folk repertoires, performed by artists across genres and taught in music education, often evoking summer’s reflective mood.
The water is wide, I cannot cross o’er,
And neither have I wings to fly.
Give me a boat that will carry two,
And both shall row, my love and I.
A ship there is, and she sails the sea,
She’s loaded deep, as deep can be;
But not so deep as the love I’m in,
And I know not how I… pic.twitter.com/kEyJAAJRfG
This platform — some twenty years in the making — needs maintenance from time to time so today there will be no Daily Consultation (15:00 UTC) while we tidy up our firmware. Instead, we make visible so-called “Evergreen” content on our client facing page as well as links to our priority projects:
We are moving our office across from the 150 State Street office we’ve occupied over ten years to an office across the street to 455 East Eisenhower, Suite 300, still proximate to the University of Michigan South Athletic Campus, with more expansive parking shared with the Olive Garden.
Enjoy the weekend! We shall reconvene LIVE again Monday, Columbus Day, October 13th when we scan codes and standards coalescing around the artificial intelligence zietgeist.
“One of the Family” 1880 | Frederick George Cotman
Spring Break has been amazing this week! Principal time is shut off! Spending time with the family is turned on! Sometimes the little things in life matter the most. Birds chirping, playing in playground, nature walk, hearing church bells! Blessed! 🙏🏻✝️#BeKindWorkHardBeGreatpic.twitter.com/bEnEpAvfnm
The NPADC is a team competition for law students to develop skills in drafting patent applications, focusing on U.S. patent law. Teams receive a hypothetical invention statement, conduct prior art searches, draft specifications and claims, and present their work to judges, including patent examiners and practitioners. For 2025, the invention was an extra-uterine system for supporting premature fetuses, indicating the complexity of tasks involved
There is no publicly available timetable for the 2026 National Patent Application Drafting Competition (NPADC) from the United States Patent and Trademark Office (USPTO) as of the latest available information. The USPTO typically releases detailed schedules for the NPADC closer to the competition year, often in the fall of the preceding year (e.g., October or November 2025 for the 2026 competition).
After months of hard work, the top five teams met at USPTO headquarters today for the final round of the 2025 National Patent Application Drafting Competition. 🏆 And the winners are … ⬇️
Thomas Jefferson was the leader in founding the United States Patent Office. Jefferson was a strong supporter of the patent system and believed that it was essential for promoting innovation and progress in the United States. As the first Secretary of State Jefferson was responsible for implementing the country’s patent system.
Article I, Section 8, Clause 8 of the United States Constitution reads as follows:
“The Congress shall have Power To promote the Progress of Science and useful Arts, by securing for limited Times to Authors and Inventors the exclusive Right to their respective Writings and Discoveries.”
In 1790, Jefferson drafted the first Patent Act, which established the procedures for applying for and granting patents. The act also created the United States Patent Office as a government agency to oversee the patent system. Jefferson appointed the first Patent Board, which was responsible for reviewing patent applications and making recommendations to the Secretary of State.
Jefferson was deeply involved in the early development of the Patent Office and was instrumental in shaping its policies and procedures. He believed that the patent system should be accessible to all inventors, regardless of their social or economic status, and he worked to streamline the patent application process to make it more efficient and user-friendly.
In recognition of his contributions to the development of the patent system, Jefferson is often referred to as the “Father of American Innovation.”
This clause grants Congress the authority to establish a system of patents and copyrights to protect the intellectual property of inventors and authors. The purpose of this system is to encourage innovation and creativity by providing inventors and authors with a temporary monopoly on their creations, allowing them to profit from their work and invest in future projects. The clause also emphasizes the importance of promoting the progress of science and the useful arts, reflecting the belief of the founders that the development of new technologies and inventions was essential for the growth and prosperity of the United States.
Over the years, the Patent Office has played a crucial role in the development of the United States as a technological leader, granting patents for inventions ranging from the telephone and the light bulb to the airplane and the computer. Today, the Patent Office is part of the United States Department of Commerce and is responsible for examining patent applications and issuing patents to inventors and companies.
Congratulations to the winners of this year’s National Patent Application Drafting Competition – Khailee, Bree, Rita, and Maria from @gwlaw, and thank you to all participants! Learn more about the competition: https://t.co/gB64fnXaM6pic.twitter.com/FWqak6Mr1m
From creating a race car safety device that protects drivers from injury to revolutionizing chemotherapy, Spartans have contributed to more than 3,300 inventions. #SpartansWillpic.twitter.com/dchCs0BFBx
New update alert! The 2022 update to the Trademark Assignment Dataset is now available online. Find 1.29 million trademark assignments, involving 2.28 million unique trademark properties issued by the USPTO between March 1952 and January 2023: https://t.co/njrDAbSpwBpic.twitter.com/GkAXrHoQ9T