Group B Proposed Changes to the 2024 Editions Complete Monograph (2650 pages)

For today’s session note the proposals listed below:

ADM1-25 Part I (p. 61)

G39-25 Part I (p. 522)

G40-25 Part I (p. 527)

G39-25 Part II (p. 535)

G144-25 (p. 740)

EB7-25 (p. 1438)

Z1-25 (p. 2582)

2025 ICC Leadership Week + Hearings Committee Action Hearings – Group B #1 | April 26 – May 6 | Orlando, Florida


Link to April Committee Action Hearing Videos

2024 Complete Change Monograph (2658 Pages)

 

“Kindergarten” c. 1885 / Johann Sperl

Safety and sustainability for any facility begins with an understanding of who shall occupy the built environment and how.  University settings, with mixed-use phenomenon arising spontaneously and temporarily, often present challenges.   Educational communities are a convergent settings for families; day care facilities among them.  First principles regarding occupancy classifications for day care facilities appear in Section 308 of the International Building Code, Institutional Group I; linked below:

2018 International Building Code Section 308 Institutional Group I-4 (Superseded in some jurisdictions)

The ICC Institutional Group I-4 classification includes buildings and structures occupied by more than five persons of any age who received custodial care for fewer than 24 hours per day by persons other than parents or guardian, relatives by blood, marriage or adoption, and in a place other than the home of the person cared far.  This group includes both adult and child day care.

We maintain focus on child day care.  Many educational communities operate child day care enterprises for both academic study and/or as auxiliary (university employee benefit) enterprises.

Princeton University Child Care Center

Each of the International Code Council code development groups fetch back to a shared understanding of the nature of the facility; character of its occupants and prospective usage patterns.

The 2024 revision of the International Building code is in production now.   Ahead of the formal, market release of the Group A tranche of titles you can sample the safety concepts in play during this revision with an examination of the documents linked below:

2019 GROUP B PROPOSED CHANGES TO THE I-CODES ALBUQUERQUE COMMITTEE ACTION HEARINGS

2019 REPORT OF THE COMMITTEE ACTION HEARINGS ON THE 2018 EDITIONS OF THE GROUP B INTERNATIONAL CODES

Search on the terms “day care” and “daycare” in the link at the top of this page to get a sample of the prevailing concepts; use of such facilities as storm shelters, for example.

“The Country School” | Winslow Homer

We encourage our safety and sustainability colleagues to participate directly in the ICC Code Development process.   We slice horizontally through the disciplinary silos (“incumbent verticals”) created by hundreds of consensus product developers every week and we can say, upon considerable authority that the ICC consensus product development environment is one of the best in the world.  Privately developed standards (for use by public agencies) is a far better way to discover and promulgate leading practice than originating technical specifics from legislative bodies.   CLICK HERE to get started.  Contact Kimberly Paarlberg (kpaarlberg@iccsafe.org) for more information.

There are competitor consensus products in this space — Chapter 18 Day-Care Occupancies in NFPA 5000 Building Construction and Safety Code, for example; a title we maintain the standing agenda of our Model Building Code teleconferences.   It is developed from a different pool of expertise under a different due process regime.   See our CALENDAR for the next online meeting; open to everyone.

 

Issue: [18-166]

Category: Architectural, Healthcare Facilities, Facility Asset Management

Colleagues: Mike Anthony, Jim Harvey, Richard Robben

Recent concepts in play in transcripts:

  • Tempered water for public hand-washing facilities
  • Walking surfaces
  • Exit signage for non-resident, non-English speaking children
  • Fire rating of corridors 
  • Bathing privacy concepts
  • Water heater controls and monitoring; mixing valves

LEARN MORE:

cdpACCESS Hearing Video Streaming Service

 

Beef Barley Soup

October 21, 2025
mike@standardsmichigan.com
No Comments

https://extension.oregonstate.edu/imported-publication/beef-barley-soup

Rain & Lightning

October 21, 2025
mike@standardsmichigan.com
, ,
No Comments

The thunderbolt steers all things.
—Heraclitus, c. 500 BC

After the rain. Personal photograph taken by Mike Anthony biking with his niece in Wirdum, The Netherlands

Today at 15:00 UTC we examine the technical literature about rainwater management in schools, colleges and universities — underfoot and on the roof.  Lightning protection standards will also be reviewed; given the exposure of outdoor athletic activity and exterior luminaires.

We draw from previous standardization work in titles involving water, roofing systems and flood management — i.e. a cross-cutting view of the relevant standard developer catalogs.   Among them:

American Society of Civil Engineers

American Society of Plumbing Engineers

ASHRAE International

ASTM International

Construction Specifications Institute (Division 7 Thermal and Moisture Protection)

Environmental Protection Agency | Clean Water Act Section 402

Federal Emergency Management Agency

FM Global

Sustainable Sites Initiative

IAPMO Group (Mechanical and Plumbing codes)

Institute of Electrical and Electronic Engineers

Heat Tracing Standards

International Code Council

Chapter 15 Roof Assemblies and Rooftop Structures

Why, When, What and Where Lightning Protection is Required

National Fire Protection Association

National Electrical Code: Article 250.16 Lightning Protection Systems

Lightning Protection

Underwriters Laboratories: Lightning Protection

Underground Stormwater Detention Vaults

United States Department of Agriculture: Storm Rainfall Depth and Distribution

Risk Assessment of Rooftop-Mounted Solar PV Systems

Readings: The “30-30” Rule for Outdoor Athletic Events Lightning Hazard

As always, our daily colloquia are open to everyone.  Use the login credentials at the upper right of our home page.

“Rainbow Connection”

The “lightning effect” seen in carnival tricks typically relies on a scientific principle known as the Lichtenberg figure or Lichtenberg figure. This phenomenon occurs when a high-voltage electrical discharge passes through an insulating material, such as wood or acrylic, leaving behind branching patterns resembling lightning bolts.

The process involves the creation of a temporary electric field within the material, which polarizes its molecules. As the discharge propagates through the material, it causes localized breakdowns, creating branching paths along the way. These branching patterns are the characteristic Lichtenberg figures.

In the carnival trick, a high-voltage generator is used to create an electrical discharge on a piece of insulating material, such as acrylic. When a person touches the material or a conductive object placed on it, the discharge follows the path of least resistance, leaving behind the branching patterns. This effect is often used for entertainment purposes due to its visually striking appearance, resembling miniature lightning bolts frozen in the material. However, it’s crucial to handle such demonstrations with caution due to the potential hazards associated with high-voltage electricity.

 

Flood Abatement Equipment

October 21, 2025
mike@standardsmichigan.com
No Comments

Vereenigde Oostindische Compagnie | Dutch East India Company

FM Global is one of several organizations that produce technical and business documents that set the standard of care for risk management in education facilities.   These standards — Property Loss Prevention Data Sheets —  contribute to the reduction in the risk of property loss due to fire, weather conditions, and failure of electrical or mechanical equipment.  They incorporate nearly 200 years of property loss experience, research and engineering results, as well as input from consensus standards committees, equipment manufacturers and others.

In July FM Global updated its standard FM 2510 Flood Abatement Equipment which should interest flood barrier manufacturers, standard authorities, industrial and commercial facilities looking to protect their buildings from riverline flooding conditions.

The following updates were proposed and mostly adopted:

  • Modifications to the opening barrier protocol to include water performance testing at lower depths;
  • Additional tests that apply to open-cellular rubber compounds (i.e., foam-type rubber) which are commonly used as gaskets on flood barriers need to be added to the Standard to sufficiently assess their quality;
  • Addition of adhesive testing. Many barrier designs use adhesives to bond the gasket material to the barrier. Adhesives are not addressed under the current protocol;
    Modify the flood abatement pump section to clarify approval of pump packages vs. wet-end only;
  • Additional requirements for electric drive and submersible flood pumps;
  • Modifications to backwater valve section to be inclusive of all types of “backwater valves” besides the traditional check valve.
  • Additional requirements for waterproofing products for building penetrations. Products in this category include collars, plugs, elastomeric seals, and types of putty.

This standard also contains test requirements for the performance of flood barriers, flood mitigation pumps, backwater valves, and waterproofing products for building penetrations, as well as an evaluation of the components comprising these products to assure reliability in the barrier’s performance.

While there are a number of noteworthy colleges and universities that have grown near rivers and lakes — twenty-five of which are listed HERE — severe weather and system failures present flooding risks to them all.

Another Data Sheet — I-40 Floods — was updated in October.   Both Data Sheets are available for download at the link below:

FM GLOBAL PROPERTY LOSS PREVENTION DATA SHEETS

You will need to set up (free) access credentials.

You may contact FM Global directly: Josephine Mahnken, (781) 255-4813, josephine.mahnken@fmapprovals.com, 1151 Boston-Providence Turnpike, Norwood, MA 02062

Our “door” is open every day at 11 AM Eastern time to discuss any consensus document that sets the standard of care for the emergent #SmartCampus.  Additionally, we dedicate one session per month to Management and Water standards.  See our CALENDAR for the next online teleconference.   Use the login credentials at the upper right of our home page.

Issue: [Various]

Category: Risk Management, Facility Asset Management

Colleagues: Mike Anthony, Jack Janveja, Richard Robben

Property Loss Prevention

 

LSU

Design Rainfall Values on Louisiana Infrastructure

October 21, 2025
mike@standardsmichigan.com

No Comments

Standards Louisiana

bucolia

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Louisiana State University Facility Services

Louisiana State University Planning, Design & Construction: Design Standards

Flood Abatement Equipment

Lightning Protection Systems

October 21, 2025
mike@standardsmichigan.com
, , , ,
No Comments

2026 Public Input Report | 2026 Public Comment Report

FEMA National Risk Index: Lightning

“Benjamin Franklin Drawing Electricity from the Sky” 1816 Benjamin West

 

Benjamin Franklin conducted his famous experiment with lightning on June 10, 1752.

He used a kite and a key to demonstrate that lightning was a form of electricity.

This experiment marked an important milestone in understanding the nature of electricity

and laid the foundation for the development of lightning rods and other lightning protection systems.

 

Seasonal extreme weather patterns in the United States, resulting in damages to education facilities and delays in outdoor athletic events — track meets; lacrosse games, swimming pool closures and the like — inspire a revisit of the relevant standards for the systems that contribute to safety from injury and physical damage to buildings: NFPA 780 Standard for the Installation of Lightning Protection Systems

FREE ACCESS

To paraphrase the NFPA 780 prospectus:

  • This document shall cover traditional lightning protection system installation requirements for the following:
       (1) Ordinary structures

       (2) Miscellaneous structures and special occupancies
       (3) Heavy-duty stacks
       (4) Structures containing flammable vapors, flammable gases, or liquids with flammable vapors
       (5) Structures housing explosive materials
       (6) Wind turbines
       (7) Watercraft
       (8) Airfield lighting circuits
       (9) Solar arrays
  • This document shall address lightning protection of the structure but not the equipment or installation requirements for electric generating, transmission, and distribution systems except as given in Chapter 9 and Chapter 12.

(Electric generating facilities whose primary purpose is to generate electric power are excluded from this standard with regard to generation, transmission, and distribution of power.  Most electrical utilities have standards covering the protection of their facilities and equipment. Installations not directly related to those areas and structures housing such installations can be protected against lightning by the provisions of this standard.)

  • This document shall not cover lightning protection system installation requirements for early streamer emission systems or charge dissipation systems.

“Down conductors” must be at least #2 AWG copper (0 AWG aluminum) for Class I materials in structures less than 75-ft in height

“Down conductors: must be at least 00 AWG copper (0000 AWG aluminum) for Class II Materials in structures greater than 75-ft in height.

Related grounding and bonding  requirements appears in Chapters 2 and Chapter 3 of NFPA 70 National Electrical Code.  This standard does not establish evacuation criteria.  

University of Michigan | Washtenaw County (Photo by Kai Petainen)

The current edition is dated 2023 and, from the transcripts, you can observe concern about solar power and early emission streamer technologies tracking through the committee decision making.  Education communities have significant activity in wide-open spaces; hence our attention to technical specifics.

2023 Public Input Report

2023 Public Comment Report

Public input on the 2026 revision is receivable until 1 June 2023.

We always encourage our colleagues to key in their own ideas into the NFPA public input facility (CLICK HERE).   We maintain NFPA 780 on our Power colloquia which collaborates with IEEE four times monthly in European and American time zones.  See our CALENDAR for the next online meeting; open to everyone.

Lightning flash density – 12 hourly averages over the year (NASA OTD/LIS) This shows that lightning is much more frequent in summer than in winter, and from noon to midnight compared to midnight to noon.

Issue: [14-105]

Category: Electrical, Telecommunication, Public Safety, Risk Management

Colleagues: Mike Anthony, Jim Harvey, Kane Howard


More

Installing lightning protection system for your facility in 3 Steps (Surge Protection)

IEEE Education & Healthcare Facility Electrotechnology

Readings: The “30-30” Rule for Outdoor Athletic Events Lightning Hazard

Churches and chapels are more susceptible to lightning damage due to their height and design. Consider:

Height: Taller structures are more likely to be struck by lightning because they are closer to the cloud base where lightning originates.

Location: If a church or chapel is situated in an area with frequent thunderstorms, it will have a higher likelihood of being struck by lightning.

Construction Materials: The materials used in the construction of the building can affect its vulnerability. Metal structures, for instance, can conduct lightning strikes more readily than non-metallic materials.

Proximity to Other Structures: If the church or chapel is located near other taller structures like trees, utility poles, or buildings, it could increase the chances of lightning seeking a path through these objects before reaching the building.

Lightning Protection Systems: Installing lightning rods and other lightning protection systems can help to divert lightning strikes away from the structure, reducing the risk of damage.

Maintenance: Regular maintenance of lightning protection systems is essential to ensure their effectiveness. Neglecting maintenance could result in increased susceptibility to lightning damage.

Historical Significance: Older buildings might lack modern lightning protection systems, making them more vulnerable to lightning strikes.

The risk can be mitigated by proper design, installation of lightning protection systems, and regular maintenance. 

Virginia Tech

Storm Shelters

October 21, 2025
mike@standardsmichigan.com
, , ,
No Comments

2024 GROUP A PROPOSED CHANGES TO THE I-CODES

Latest News and Documents

“Landscape between Storms” 1841 Auguste Renoir

 

When is it ever NOT storm season somewhere in the United States; with several hundred schools, colleges and universities in the path of them? Hurricanes also spawn tornadoes. This title sets the standard of care for safety, resilience and recovery when education community structures are used for shelter and recovery.  The most recently published edition of the joint work results of the International Code Council and the ASCE Structural Engineering Institute SEI-7 is linked below:

2020 ICC/NSSA 500 Standard for the Design and Construction of Storm Shelters.

Given the historic tornados in the American Midwest this weekend, its relevance is plain.  From the project prospectus:

The objective of this Standard is to provide technical design and performance criteria that will facilitate and promote the design, construction, and installation of safe, reliable, and economical storm shelters to protect the public. It is intended that this Standard be used by design professionals; storm shelter designers, manufacturers, and constructors; building officials; and emergency management personnel and government officials to ensure that storm shelters provide a consistently high level of protection to the sheltered public.

This project runs roughly in tandem with the ASCE Structural Engineering Institute SEI-17 which has recently updated its content management system and presented challenges to anyone who attempts to find the content where it used to be before the website overhaul.    In the intervening time, we direct stakeholders to the link to actual text (above) and remind education facility managers and their architectural/engineering consultants that the ICC Code Development process is open to everyone.

The ICC receives public response to proposed changes to titles in its catalog at the link below:

Standards Public Forms

2024/2025/2026 ICC CODE DEVELOPMENT SCHEDULE

You are encouraged to communicate with Kimberly Paarlberg (kpaarlberg@iccsafe.org) for detailed, up to the moment information.  When the content is curated by ICC staff it is made available at the link below:

ICC cdpACCESS

We maintain this title on the agenda of our periodic Disaster colloquia which approach this title from the point of view of education community facility managers who collaborate with structual engineers, architects and emergency management functionaries..   See our CALENDAR for the next online meeting, open to everyone.

Readings:

FEMA: Highlights of ICC 500-2020

ICC 500-2020 Standard and Commentary: ICC/NSSA Design and Construction of Storm Shelters

IEEE: City Geospatial Dashboard: IoT and Big Data Analytics for Geospatial Solutions Provider in Disaster Management

 

Americas Infrastructure Report Card

October 21, 2025
mike@standardsmichigan.com
No Comments

ASCE Standards Catalog | Standards Open for Public Comment

Electrical Trade Labor Standards

October 20, 2025
mike@standardsmichigan.com
No Comments

Free Journeyman Electrician Practice Test 2025 Study Guide

United States national electrical trade standards prioritize safety, reliability, and economic efficiency in electrical systems. Governed primarily by the National Electrical Code upon which the University of Michigan has had a vote since 1996.

The NEC outlines requirements for wiring, equipment installation, grounding, and overcurrent protection to prevent hazards like electrical shocks, fires, and equipment failures. Compliance ensures safe operation in residential, commercial, and industrial settings. Standards also promote energy efficiency, encouraging practices like proper insulation, energy-efficient lighting, and renewable energy integration to reduce costs and environmental impact.

Organizations like the Occupational Safety and Health Administration (OSHA) and Underwriters Laboratories (UL) further enforce safety through regulations and product certifications. Adherence to these standards minimizes risks, ensures system longevity, and supports economic benefits through reduced energy waste and maintenance costs, fostering a safe and sustainable electrical infrastructure.

European Union electrical trade standards prioritize safety, interoperability, and economic efficiency across member states. Governed by the Low Voltage Directive (LVD) 2014/35/EU and harmonized standards from the European Committee for Electrotechnical Standardization (CENELEC), these regulations ensure electrical equipment operates safely between 50-1000V AC or 75-1500V DC. Standards like EN 60335 address appliance safety, while EN 50110 outlines safe maintenance and operation practices. Compliance with CE marking requirements certifies adherence to safety, health, and environmental standards, facilitating market access.

For economy, the EU promotes energy efficiency through directives like the Ecodesign Directive 2009/125/EC, mandating efficient lighting, motors, and renewable energy integration to reduce consumption and costs. National regulations align with EU standards, ensuring consistency. These measures minimize electrical hazards, enhance system reliability, and support sustainability by reducing energy waste, fostering cost-effective, safe electrical infrastructure across the EU’s diverse markets.

Non-profit organizations and unions play a critical role in training electricians, ensuring skilled, safe, and competent professionals. Organizations like the National Electrical Contractors Association And unions such as the International Brotherhood of Electrical Workers Offer structured apprenticeship programs combining classroom instruction with hands-on training.

These programs cover electrical theory, National Electrical Code compliance, safety practices, and emerging technologies like renewable energy systems. Non-profits often provide certifications, scholarships, and continuing education to promote workforce development. Unions advocate for fair wages and safe working conditions, while their training centers emphasize practical skills, ensuring electricians meet industry standards and contribute to reliable, efficient electrical systems.

Join us today with the login credentials at the upper right of our home page.

 

Layout mode
Predefined Skins
Custom Colors
Choose your skin color
Patterns Background
Images Background
error: Content is protected !!
Skip to content